Supervisore Elettrico
4 settimane fa
Milano, Provincia di Milano; Lombardia, Italia
Kirby Group Engineering
Tempo pieno
Gratuito con email o Google
Salva questo lavoro e mantieni la tua ricerca organizzata
Crea un account gratuito per salvare lavori, creare avvisi e tornare a questa inserzione dalla tua dashboard.
Gratuito con email o Google
Continuando accetti i nostri Termini & Informativa sulla privacy.
Permanent position available with a considerable portfolio of works for the next 5+ years
To build your career by assisting in the delivery of ‘leading edge’ engineering projects.
To work with a vibrant, agile and multi-functional team in delivering projects on time, safely, to budget and to the required quality standards.
To benefit from Kirby’s Career Development Programmes that will enhance your leadership capability.
Excellent package on offer with room for negotiations
About Kirby Group Engineering
Kirby Group Engineering is an international multi-disciplinary engineering services contractor and leading provider of high-value engineering services to a number of ‘blue chip’ companies. Operating across Ireland, the UK, Europe and South Africa, Kirby has become the engineering service provider of choice in growth segments such as pharmaceuticals, data centres and power transmission and distribution. Our culture is innovative, collaborative and performance focused. The successful candidate will have the opportunity to grow and develop in a company committed to developing talent and rewarding performance.
The role of the Electrical Site Supervisor is to support the Site Manager in the organization and co-ordination of site-based activities and to lead and co-ordinate teams of Electrical Engineering trade professionals on site. They will lead their teams to deliver to quality, on time and to budget in a safe and efficient manner. Electrical Site Supervisor Responsibilities
In conjunction with your project team, you will be responsible for the execution of various stages of a project in line with the Kirby Way:
Commercial
Schedule
Develop 2 week look ahead and agree it with CM at weekly meeting.
Coordinate work with other trades in your area through whiteboard and directly.
Ensure your scope is construction complete for agreed start dates of testing and commissioning.
Review and agree area site set-up with C.
Ensure temp power is available for directs and subcontractors prior to required date. Understand Quality objective of Project – snag free systems on time. Review and understand Quality Control Plan which is based on 6M’s. Implement Quality Control Plan on site. Ensure only specified materials are used for your scope of installation. Complete Weekly Quality Audits and check lists. Clear quality audit actions as soon as possible. Identify snag items as the installation progresses – stand down crew forTBT if snags are repeated. Clear snag items to suit walkdown schedule. Collate and File all relevant documentation delivered with materials, plant and equipment. Ensure materials, plant and equipment are installed to specification and manufacturers recommendations. Ensure installation is in accordance with P&IDs and Isometrics. Understand and follow the requirements associated with maintaining the correct files on site. Ensure all your personnel have the relevant training for the allocated tasks. Review and understand the safety objective of the project – target Zero incidents and understand why Planning is particularly important for MIMO, Working at Height and Working with/around electricity Coordinate work with other trades in your area (co-sign SPA’s where possible) Enforce rule that no persons to work underneath other trades working at height Ensure housekeeping issuesare highlighted and noted on daily whiteboards All materials and tools used while working at height must be secured, tethered or removed from location Large cable pulls to have an exclusion zone in the relevant area, if too disruptive to other trades then cable pulls must be done through night work. Night work needs to be agreed in advance with CM Ensure that cleaning takes place regularly or as work is carried out and place of work and access routes are kept clear. Ensure all your personnel have the relevant training for the allocated tasks. The operation of a protective or control device is to be done by Intel or a Kirby AP, no other person is authorised to switch on or off a protective or control device Ensure that all plant and machinery including power and hand tools are in a good condition, defect free and that statutory, in-house inspection and maintenance procedures are carried out as required. Ensure that any defects in plant and equipment are rectified or remove defective items as soon as possible Ensure that you complete ‘Site Supervisor Safety Audit’ Clear any actions from audit as soon as possible Conduct “Tool Box” talks and keeps attendance records in the site safety file. Inform the employees of their safety performance on site and any improvements needed through the behavioural notice card system – Green, Yellow and Red Escalate incident situations through informing CM or PM as soon as possible Participate in incident investigation Implement determined incident remedial actions to prevent reoccurrence of incident as soon as possible
Ensure temp power is available for directs and subcontractors prior to required date. Understand Quality objective of Project – snag free systems on time. Review and understand Quality Control Plan which is based on 6M’s. Implement Quality Control Plan on site. Ensure only specified materials are used for your scope of installation. Complete Weekly Quality Audits and check lists. Clear quality audit actions as soon as possible. Identify snag items as the installation progresses – stand down crew forTBT if snags are repeated. Clear snag items to suit walkdown schedule. Collate and File all relevant documentation delivered with materials, plant and equipment. Ensure materials, plant and equipment are installed to specification and manufacturers recommendations. Ensure installation is in accordance with P&IDs and Isometrics. Understand and follow the requirements associated with maintaining the correct files on site. Ensure all your personnel have the relevant training for the allocated tasks. Review and understand the safety objective of the project – target Zero incidents and understand why Planning is particularly important for MIMO, Working at Height and Working with/around electricity Coordinate work with other trades in your area (co-sign SPA’s where possible) Enforce rule that no persons to work underneath other trades working at height Ensure housekeeping issuesare highlighted and noted on daily whiteboards All materials and tools used while working at height must be secured, tethered or removed from location Large cable pulls to have an exclusion zone in the relevant area, if too disruptive to other trades then cable pulls must be done through night work. Night work needs to be agreed in advance with CM Ensure that cleaning takes place regularly or as work is carried out and place of work and access routes are kept clear. Ensure all your personnel have the relevant training for the allocated tasks. The operation of a protective or control device is to be done by Intel or a Kirby AP, no other person is authorised to switch on or off a protective or control device Ensure that all plant and machinery including power and hand tools are in a good condition, defect free and that statutory, in-house inspection and maintenance procedures are carried out as required. Ensure that any defects in plant and equipment are rectified or remove defective items as soon as possible Ensure that you complete ‘Site Supervisor Safety Audit’ Clear any actions from audit as soon as possible Conduct “Tool Box” talks and keeps attendance records in the site safety file. Inform the employees of their safety performance on site and any improvements needed through the behavioural notice card system – Green, Yellow and Red Escalate incident situations through informing CM or PM as soon as possible Participate in incident investigation Implement determined incident remedial actions to prevent reoccurrence of incident as soon as possible